Toa Penetrating Sealer

Spesifikasi:

TECHNICAL INFORMATION
Type : Epoxy / Polyamide Primer
Color : Clear Red
Film appearance : Semi-Gloss
Specific gravity : 1.06 + 0.05
Solid by volume : 100 %
Flash point : 42 ?C
Minimum Maximum Recommended
Dry film thickness (Microns) 50 100 50
Wet film thickness (Microns) 50 100 50
Theoretical coverage. m2 / Liter 20.0 10.0 20.0
m2 / Gallon 75.7 37.9 75.7
Practical coverage. m2 / Liter 13.0 6.5 13.0
m2 / Gallon 49.0 24.6 49.0
Remark : Actual Surface coverage will depend on surface irregularities, Mixing, Application Condition
method and technique; as well as the structure and dimensions of the object to be coated.
Temperature 25 ?C 30 ?C 35 ?C
Touch dry Surface dry 4.5 hrs. 4 hrs. 3.5 hrs.
Recoat dry Hard dry 6.5 hrs. 6 hrs. 5.5 hrs.
Full cure Minimum 10 hrs. 9 hrs 8 hrs.
Maximum - - -
Potlife 2 hrs. 2 hrs. 1.5 hrs.
Remark : Drying times are generally related to air circulation, temperature, film thickness and number
of coats, and will be affected correspondingly

APPLICATION
Mixing Ratio Part A Part B
By Volume 2.2 1
By Weight 70 30

APPLICATION SYSTEM
Surface Preparation
Wall & Floor : For New concrete - The concrete prior to laying plastic sheets to block moisture from underground.
Then it should be left for curing concrete to solid and dry for about 3-4 weeks. Then, clean the surface
free from dust, dirt, grease and most importantly, the surface is completely dry.
(Check moisture content must be less than 10%)
: For Old concrete - To remove the old paint film which loosely adhesion to as much as possible by
Scraping with a shovel or Grinding machine to enhance adhesion. Then, clean the surface free from
grease and oil with suitable solvent. Before primer coating should clean all surfaces free from dust,
dirt, grease and most importantly, the surface is completely dry. (Check moisture content must be
less than 10%).
: For Floor Hardener or Surface glossy finish :
: Concrete surface preparation by using dust free captive blasting units, grinding equipment,
sand blasting for increase adhesion of coating.
: Inspect the concrete for bug holes void, fin and other imperfections. Protrusions shall be ground
smooth while voids shall be filled with Floorguard Putty or other suitable filler and polishing of
surface with moltoprene disk.
: After cleaning, repair surface defects and remove detericrated previous coatings.
(Check moisture content must be less than 10%).
Before Recoat by Topcoat : Remover all oil, grease, dirt, oxide and other foreign material by cleaning per SSPC-SP1,
Solvent Cleaning before coating.
: If over 7 days gives cleaning surface by sand paper no. 320-400 and cleaning surface per
SSPC-SP1, Solvent Cleaning before coating.
: Surface repaire (cracks, pores, holes) done with TOA Epoxy putty (for Wal) or Floorguard Putty
(for Floor)and polishing of surface with moltoprene disk.
Paint System (Dry Film Thickness)
Concrete protective Coating : Primer Penetrating Sealer 50 microns x 1 coat
For Wall : Topcoat Epoguard Enamel
(for inside area)
50 microns x 2 coats
or
Topguard
(for outside area)

For Floor : Primer Penetrating Sealer 50 microns x 1 coat
: Topcoat Floorguard 100
(for inside area)
50 microns x 2 coats
or
Floorguard PU 100
(for outside area)
50 microns x 2 coats
Recommendation : The proper relative humidity in the work shall not exceed 85% RH.
: The temperature of the substrate should be minimum 10 ?C and at least 3 ?C above the dew point of the air ,
temperature and relative humidity measured in the vicinity of the substrate for prevent moisture and water drop
on substrate effective adhesion and drying time.

Dimensi:

Deskripsi:
FEATURES
: PENETRATING SEALER is a high solid epoxy 2-pack chemically cured. It is designed as excellent
adhesion and penetrat on concrete, green conrete, floor hardener, ceramic tile, excellent adhesion, toughness,
hardness, water resistance film coating.
: As a primer for concrete, green concrete,floor hardener, fiberglass, wood and ceramic tile

TKDN
0 %
Bagikan