Mcfa - Perlengkapan Sinyal Tanda Kebakaran

Spesifikasi:

SPESIFICATION

Model  : YF - 1 5L
Power Souce : 110V AC 50/60 Hz or 220V AC 50/60 Hz
Standby Battery : 24V DC
Charging Voltage : Below 26.4V DC 450 mA Irickle Charging
Circuit Voltage : 24 V DC Operation Voltage, Under 5 V 32 mA
Rated Inpendance : Under 50n Ground Resistence Above 2 Mn
Detector Conection : No Limitation for Conventional Rate of Rise Heat / Fixed Temperature Heat Detectors Up to 30 Photoelectric Smoke Detector per Zone
E.O.L Resistor : 10 Kn
No. Of Indicators : 1.2 times of the number of zone ( LEDIndication Lamp )
No. Of Bells : 1.2 times of the number of zone
Cabinet Material : Powder Coating Steel
Main Audio : Mono Tone Sounder Lobove 85 dB for 1 m distance
Alarm Relay Contact : 2 set No of Voltage No contact, capacity AC 250V / 7A

Dimensi:

5 Zone

10 ZOne

15 Zone

20 Zone

30 Zone 

40 Zone

Deskripsi:
Circuit detection requires a period of accumulation time to reset the detector, and detection of the second stage of accumulation, thus reducing the chances of a false alarm caused by interference from ordinary circuits, and improving the dependability of the Central Control Unit.

Stand-by Battery Protection System

During blackout, if the stand-by battery has discharged to below DC18V, it will automatically stop discharging, thus increasing battery life.

Quality Control

The control panel switches and all of the base board components of this unit are all certified by CNS and CE. All units must pass stringent quality inspections before leaving the factory, ensuring that each will be performing as expected.

User-friendly Design

All circuit boards use a modular design; the external lines are also separated from the terminal circuit board, with protections implemented on the input end. If a faulty power supply is connected to the circuit board caused fault, only the affected circuit board needs to be exchanged without disconnecting the external lines, thus greatly improving maintenance and inspection efficiency.

Exterior Design

Exterior DesignThis unit's circuit display uses high-end heat-resistant plastic, making its stream-lined exterior poised and elegant. With the circuits accessorized with indication plates, it makes all information regarding the buildings, floors and circuit properties clear at a glance.

Other Application

This Central Control can also be collocated into a 3-in-1 system with our Broadcast Host and Emergency Telephone Unit, creating a system that both looks and performs like a unity, and enhance the beauty of in-site use.

TKDN
0 %